CONSTRUCTION SEQUENCE FOR LONG-TERM OR DELAYED INTERMEDIATE COUPLER SYSTEM

The following shows the construction sequence when using GTI Zero Void Intermediate Couplers® in a “long-term” or “delayed” situation.  This may be in a structure that will be added to over time or at a location needing added corrosion protection until the connection is made.



The construction sequence demonstrates how the GTI Zero Void Intermediate Coupler® works in a long-term or delayed situation.  The tendon is installed as a stressing-end with a large pocket former prior to concrete placement; the tendon is stressed using a threaded barrel anchor; the tendon tail is cut using a GTI Plasma Cutter; the temporary intermediate cap is installed and the pocket former recess grouted; the coupler comes shop attached to the new pour’s tendon and is attached to the threaded barrel anchor after removing the temporary drypack; and, the finished product in the concrete.
 
 

Contact GTI Sales for quotes.

Contact GTI Orders to place orders.

See www.gti-usa.net/patents.shtml for a listing of many of the patents licensed to GTI, including patents that may cover one or more of the products identified on this page.

   